Language selection: Switch to the Turkish version →
Abstract. Bearing capacity describes the limiting resistance of soil against shear failure beneath a foundation. Reliable design requires more than a calculated failure pressure: settlement, groundwater, load eccentricity, stratification, seismic actions, construction and uncertainty must also be assessed. This scholarly tutorial compares the principal theoretical, analytical, empirical, experimental and numerical method families and provides eight step-by-step worked examples.
Keywords: bearing capacity, general shear failure, Terzaghi, Prandtl–Reissner, Meyerhof, Hansen, Vesić, Skempton, SPT, CPT, piles, settlement, Eurocode 7, Turkish Seismic Code.
1. Definitions and design philosophy
The gross ultimate bearing pressure, , is the average base pressure at failure. The net ultimate pressure excludes the original effective overburden at foundation level. Under the traditional allowable stress design (ASD) format:
Here is a clearly defined global factor of safety. Match net applied pressure with net resistance, or gross pressure with gross resistance. Effective versus total stress and service versus factored actions must not be mixed.
Notation: = foundation width (short side), = length, = embedment, = effective cohesion (kPa), = effective friction angle, = undrained strength (kPa), = soil unit weight (kN/m³), and = effective surcharge (kPa). Bearing pressures have units kN/m² = kPa.
2. Failure mechanisms and theoretical origin
General shear failure commonly exhibits a pronounced peak and a continuous failure mechanism in dense sand or stiff clay. Local shear failure involves progressively developing plastic zones; punching shear is associated with large penetration and poorly defined surface heave in compressible materials. The mechanism affects the mobilized strength and validity of any simplified equation.
Prandtl (1921) and Reissner provided plasticity/limit-equilibrium foundations for the and contributions in a homogeneous half-space. The Mohr–Coulomb strength envelope is
The soil self-weight contribution, , requires additional assumptions or calibrated approximations and therefore differs between published methods.
3. Classical shallow-foundation theories
3.1 Terzaghi (1943)
For a shallow strip footing on a horizontal homogeneous ground surface under a vertical concentric load, the familiar three-component equation is
The contributions are cohesion, surcharge and soil self-weight. Terzaghi's original factors and geometric corrections are not automatically interchangeable with later formulations.
3.2 Meyerhof (1951, 1953, 1963)
Meyerhof extended the assessment to foundation shape, embedment, inclination and eccentricity. One commonly quoted Meyerhof expression is
For local shear, historical approximations such as and are sometimes discussed. They are not universal prescriptions for soft or loose soils, where deformation checks remain essential.
3.3 Brinch Hansen and Vesić
A broadly used generalized bearing capacity expression is
The dimensionless factors respectively address shape (), depth (), load inclination (), base inclination () and ground inclination (). Apply a consistent set from a clearly identified formulation.
For general shear, widely adopted bearing capacity factors are:
Representative, non-identical options for the soil self-weight factor:
| 1.00 | 5.14 | 0.00 | |
| 6.40 | 14.83 | 5.39 | |
| 18.40 | 30.14 | 22.40 | |
| 33.30 | 46.12 | 48.03 | |
| 64.20 | 75.31 | 109.41 |
One explicitly chosen correction set (Vesić-type; level base and ground, vertical central load; ):
When , the cohesion term and its corresponding correction factors vanish. Different load, soil or geometric conditions require the complete method-specific factor set.
3.4 Skempton (1951): undrained clays
For short-term total-stress analysis with :
For the ideal surface strip condition, ; Skempton's shape and embedment factors modify it for actual geometry. Disturbance, strength anisotropy, rate effects and subsequent consolidation should be investigated.
4. Groundwater and drainage
Effective stress satisfies , and submerged unit weight is
With the water table at footing base, the surcharge term must use the relevant overburden above base level, while the self-weight contribution generally uses an appropriate submerged unit weight below it. Water below base affects the failure zone according to its depth: simplified interpolation rules have limited, method-dependent applicability.
Undrained short-term analysis: use and total stresses. Drained long-term analysis: use , and effective stresses. Construction time and loading history can require both evaluations.
5. Eccentric and inclined loading
Under Meyerhof's effective area concept:
The effective-area idealization is not the same as the actual contact stress distribution. Consider biaxial moments, uplift/contact loss, horizontal load , sloping bases, ground slopes and sliding. Large mats/rafts further require consideration of soil–structure stiffness and differential settlements.
6. Layered ground, special soils and rock foundations
Layered soil: a stronger crust overlying weak material may fail through punching, even where the shallow layer alone appears strong. The thickness ratio , strength contrast and interface conditions control the result. Treating the entire zone as homogeneous strong soil can be unsafe.
Special conditions: foundations near slopes, excavations or edges; variable fill; karst cavities; anisotropy; partial saturation; frost and scour warrant dedicated checks. For rock foundations, intact core compressive strength alone is insufficient: joints, block failure, discontinuity orientations and spacing, and rock-mass deformability must be considered.
7. In-situ and empirical methods
| Test / approach | Information and use | Key limitation |
|---|---|---|
| SPT | Corrected ; stratigraphy, friction-angle and settlement correlations | Energy, overburden and soil-specific corrections |
| CPT/CPTu | Continuous , sleeve friction, pore-pressure response | Soil behavior type, drainage and local calibration |
| Pressuremeter (PMT) | Limit pressure and deformation modulus | Testing quality and model-specific correlations |
| Dilatometer (DMT) | Stress history, lateral stress and stiffness indices | Empirical, soil-dependent interpretation |
| Field vane | In-situ in soft cohesive deposits | Rate and anisotropy effects |
| Plate load test (PLT) | Measured load–settlement curve | Size and influence-depth scale effects |
| Static pile load test | Load–settlement response; optional toe/shaft instrumentation | Load-test protocol and interpretation criterion |
Some correlations for allowable bearing pressure based on SPT/CPT are settlement-calibrated, rather than direct predictions of ultimate shear failure. Distinguish direct CPT-based bearing resistance estimates from indirect estimates using derived and values.
8. Settlement as an independent performance limit
A simplified immediate elastic settlement estimate is
where is stiffness, is Poisson's ratio and represents selected geometry/rigidity effects. For a normally consolidated clay stratum, one-dimensional primary consolidation is
Stress increments can be estimated using Boussinesq solutions or a preliminary 2:1 spread approximation; layered elasticity and FEM can be used for more complex cases. Assess total and differential settlement, rotation and structural sensitivity—not just a single averaged value.
9. Pile and deep-foundation capacity
The ultimate axial compressive resistance of an individual pile can be represented as
The method for clay assumes . The effective-stress method commonly takes ; mixed methods and CPT-based direct methods are also used. Installation method, load tests, group/block failure, downdrag (negative skin friction), different toe/shaft mobilization curves, lateral resistance and settlement require separate checks.
10. Seismic effects, numerical methods and design codes
Seismic/cyclic conditions: inertial loading changes load inclination and may alter effective stresses; liquefaction, cyclic softening and post-earthquake settlement can govern. Seismic bearing capacity models should not be blended indiscriminately with static factors.
Numerical approaches: finite elements (FEM), finite differences (FDM), boundary elements (BEM), finite-element limit analysis (FELA), load stepping and strength reduction can examine layered, nonlinear and three-dimensional behavior. Verify mesh convergence, domain boundaries, drainage assumptions, dilatancy/flow rules, interfaces, material calibration and independent benchmark solutions.
ASD compares service loading with allowable resistance after a global . The Turkish Building Earthquake Code (TBDY 2018) uses an appropriate design-resistance / factored-action format for applicable shallow-foundation cases; Example 6 illustrates only in its defined context. Eurocode 7 applies limit-state design and relevant partial factors under the applicable code edition and National Annex. An additional ASD global factor should not be automatically imposed on a partial-factor design.
11. Eight fully worked calculations
Example 1 — Strip footing on sand: Vesić + ASD
Given m, m, , , kN/m³, deep groundwater, and service force kN/m.
Because kPa, the idealized bearing resistance check passes. Foundation self-weight, net-load definition and settlement require separate consideration.
Example 2 — Rectangular footing: shape and depth
Take m, m, m and the same soil as Example 1. With the specified Vesić-type factors:
This quantifies how geometry and embedment change the predicted capacity, with .
Example 3 — Groundwater rises to footing base
Repeat Example 1, but take below-base kN/m³ and kN/m³:
The allowable gross value decreases by about 22.7% from Example 1. A service pressure of 220 kPa would no longer pass the simplified check.
Example 4 — Undrained clay: Skempton
For m, m, kPa, kN/m³, idealized and :
Actual footing shape/depth corrections and consolidation settlement must also be examined.
Example 5 — Eccentric load and effective area
Given m, m, kN, kNm and :
On the illustrative effective geometry of Example 2, kPa. This is only a capacity-model comparison; gross/net stresses, contact distribution and other limit states must be checked consistently.
Example 6 — Illustration of a TBDY 2018 factored resistance check
Use the soil from Example 1. In the simplified expression selected for this example, , all other correction factors equal 1, and factored design pressure kPa:
This illustrative design-resistance check passes. A factored load effect cannot be directly compared with the ASD service pressure in Example 1. Confirm the governing code provisions and coefficients for any real project.
Example 7 — Settlement may govern even where strength is adequate
Immediate settlement: kPa, m, kPa, , :
Separate consolidation scenario: m, , , kPa, kPa:
With an assumed settlement limit of 25 mm, the second scenario fails the serviceability requirement. These two examples use different inputs and are not added together here.
Example 8 — Single pile: base plus shaft resistance
Assume diameter m, mobilized shaft length m, kPa and kPa:
The final line is an illustrative ASD assumption of . Downdrag, group effects, installation, settlement and pile load testing must not be omitted in design.
12. Method selection and practical checklist
| Situation | Suitable starting point | Essential independent checks |
|---|---|---|
| Homogeneous sand / strip footing | Terzaghi or Vesić | Water, friction-angle sensitivity, settlement |
| Short-term undrained clay | Skempton and | Short/long term, anisotropy, consolidation |
| Rectangular footing, inclined/eccentric load | Meyerhof, Hansen or Vesić | Effective area, contact stress, sliding |
| Layered soil / adjacent slope | Layered or slope-specific models | Punching, global stability, numerical benchmark |
| Large raft | Analytical methods plus FEM | Soil–structure interaction, differential settlement |
| Piles | /, CPT and load testing | Downdrag, group effects, settlement |
| Rock foundation | Rock-mass analysis | Joint sets, block stability, deformation |
Recommended workflow: (1) establish the stratigraphic model from borings and in-situ tests; (2) identify groundwater and drainage stages; (3) define consistent action combinations and effective geometry; (4) select a coherent theoretical/empirical method; (5) verify ultimate design resistance under the applicable code; (6) check settlement and other limit states; and (7) document parameter sensitivity and uncertainty.
13. Selected references
- Prandtl, L. (1921). Über die Eindringungsfestigkeit plastischer Baustoffe. ZAMM, 1, 15–20.
- Terzaghi, K. (1943). Theoretical Soil Mechanics. Wiley.
- Meyerhof, G. G. (1951). The ultimate bearing capacity of foundations. Géotechnique, 2(4), 301–332.
- Meyerhof, G. G. (1953). The bearing capacity of foundations under eccentric and inclined loads. Proceedings, 3rd ICSMFE, 1, 440–445.
- Meyerhof, G. G. (1963). Some recent research on the bearing capacity of foundations. Canadian Geotechnical Journal, 1(1), 16–26.
- Skempton, A. W. (1951). The bearing capacity of clays. Building Research Congress, Division 1, 180–189.
- Brinch Hansen, J. (1970). A revised and extended formula for bearing capacity. Danish Geotechnical Institute Bulletin, 28, 5–11.
- Vesić, A. S. (1973). Analysis of ultimate loads of shallow foundations. ASCE Journal of SMFD, 99(SM1), 45–73.
- Schmertmann, J. H. (1970). Static cone to compute static settlement over sand. ASCE Journal of SMFD, 96(SM3), 1011–1043.
- USACE EM 1110-1-1905 — Bearing Capacity of Soils (1992).
- FHWA — Geotechnical Engineering Circular No. 6: Shallow Foundations (2002).
- AFAD. Turkish Building Earthquake Code (TBDY 2018), relevant soil and foundation provisions.
- CEN. Eurocode 7: Geotechnical Design, applicable edition and National Annex.
This resource is an academic instructional review with worked examples; it does not replace project-specific geotechnical design documentation.